The facility hardware improvement list of BSCI social responsibility factory audit -The Leading Factory Audit & Inspection Consulting Company from China to Asia | TRANWIN
Hotline

GRS认证

Current LocationHome> Certification Factory Audit>BSCI Factory Audit>The facility hardware improvement list of BSCI social responsibility factory audit

The facility hardware improvement list of BSCI social responsibility factory audit

Source: 2019-10-21 11:30 by admin The facility hardware improvement list of BSCI social responsibility factory audit Read: 591

The facility hardware improvement list of BSCI social responsibility factory audit is as follows: 


Now more and more customers will ask the factory to conduct inspections. More and more people will accept the BSCI social responsibility audit. The social responsibility audit is one of the most acceptable inspections. The following content is provided by our techincal team on how to rectify the hardware conditions of the factory.


The first step is to ensure that each safety exit is equipped with an emergency light, a safety exit sign and a safe escape map.


The fire exit should be attached with a safety exit sign.


The escape map requires a description of the current location and the location of the fire-fighting equipment, which is marked with a red sign.


Each office department must have a department name tag.


There are expired fire extinguishing equipment in the workshop and in the dormitory. Please handle it promptly and replace it in time. And each fire extinguisher must be inspected monthly. It must be signed by a special person. The person signing is preferably the same person. This person must also be in the factory.


Each workshop and warehouse must have an escape arrow indication, which can be purchased according to the provided template.


The secondary container of the chemical warehouse standard, and classified storage, posting MSDS (material safety material list), fire equipment (adding fire sand), medicine box and standard eye wash table (sufficient water pressure), special person to manage eye wash, Add a riot light.


Employees do not wear labor insurance products as standard, such as earplugs in workshops higher than 85 decibels.


If there is no dispensing box in each workshop or department, the dispensing box is required and the medicines must be complete. There should be no internal medicine and expired medicines. There must be a blank drug record, first aid procedure, first aid name phone number and local hospital phone number. First responder It should be trained by a doctor with the qualification of a doctor, and the doctor's qualification certificate should be attached to the inspection materials.


Factory waste needs to be classified, recyclable and non-recyclable.


The restaurant staff needs to wear masks and sanitary ware when cooking.


The staff quarters are also equipped with fire-fighting equipment according to the fire-fighting law zone. Fire extinguishers should be installed at obvious and convenient locations and must not affect safe evacuation. Fire extinguishers should be set to be stable and their brand names must be facing outwards.


Fire drills are necessary, 2 times a year, all employees are required to participate, and there are training records and exercises photos. 4 types of photos: evacuation, collection of counts, professionals to demonstrate fire-fighting, personal fire-fighting experience by employees.


All machines must have a daily security record of the professional and cannot appear on Sundays.


It is necessary to conduct training on production safety training and disease prevention for new employees, such as AIDS awareness training and SARS flu prevention and training.


Factory workshops and offices are required to post BSCI customer supplier standards.


Factory pest control plan and measures taken, such as rat and rodenticides.


All electrical devices (electric gates/inserts/switches, etc.) in the workshop must be equipped with locking devices.


All machines must have a daily security record of the professional and cannot appear on Sundays.


It is necessary to conduct training on production safety training and disease prevention for new employees, such as AIDS awareness training and SARS flu prevention and training.


Factory workshops and offices are required to post BSCI customer supplier standards.


Factory pest control plan and measures taken, such as rat and rodenticides.


All electrical devices (electric gates/inserts/switches, etc.) in the workshop must be equipped with locking devices.

Latest Articles
Contact Us

SHANGHAI TRANWIN MANAGEMENT CONSULTING CO.,LTD.


CONTACT: Mr. David Lee

E-MAIL: chaowang@tranwin.net(prefered)